| Sign In | Join Free | My xpandrally.com |
|
Brand Name : LONROY
Place of Origin : Guangdong, China
MOQ : 1
Furnace temperature range : 1200ºC, 1400ºC, 1700ºC
Heating speed : 0 ~ 100 degrees/min
Expansion measurement range : ±5mm
Measurement resolution : 0.1 ~ 1um
Sample dimensions : (2 ~ 15) × (2 ~ 15) × (20 ~ 150) mm
System measurement error : ±0.1 ~ 0.5%
Power supply voltage : 220V±10%
Power consumption : 2KW
Protection class : IP57
Temperature spacing : 1ºC
Transmission type : Non-friction linear bearing
Computer interface : Standard
Voltage : 220 V
Sample shape : Square/round
Measurement automation : Automatic calibration
PCY-1200 high temperature thermal expansion instrument thermal expansion coefficient instrument thermal expansion meter
1.Product introduction
The instrument mainly measures the U(K) value of the heat transfer coefficient of vacuum glass, which complies with the standard JC/T2708-2022 "Test method for heat transfer coefficient of vacuum glass". It can also test homogeneous plate materials such as plastics, rubber, glass, fiber, benzene board, extruded board, foamed concrete, hollow glass, wood board, various insulation materials, etc. At the same time, it can measure the thermal conductivity of various materials such as granular materials, bulk materials, soft materials, etc. Applicable standards: GB/T10294-2008 "Determination of steady-state thermal resistance and related properties of insulation materials"; GB/T3399-1982 "Test method for thermal conductivity of plastics-heat-protected flat plate method"; GB/T10801.1-2002 "Polystyrene foam plastics for thermal insulation" specifies the measurement of thermal conductivity of polyurethane rigid foam materials; GB/T10801.2-2002 "Extruded polystyrene foam plastics for thermal insulation (XPS)" specifies the measurement of thermal conductivity of extruded polystyrene foam plastics; GB/T3139-2005 "Test method for thermal conductivity of fiber reinforced plastics"; GB/T 17794-2008 "Flexible foam rubber and plastic insulation products".
PCY-1200 high temperature thermal expansion instrument thermal expansion coefficient instrument thermal expansion meter
2. Product Parameter
| furnace temperature range | 1200ºC, 1400ºC, 1700ºC by customer choice. |
| heating speed | 0 ~ 100 degrees/min adjustable, computer program temperature control. |
| expansion value measurement range | ±5mm |
| measuring expansion value resolution | 0.1 ~ 1um, automatic calibration range |
| the sample range | (2 ~ 15) × (2 ~ 15) × (20 ~ 150) mm, square/round can be. |
| system measurement error | ±0.1 ~ 0.5%. |
| power supply voltage | 220V±10%, 2KW. |


|
|
High Temperature Thermal Expansion Instrument Meter Tester Deformation Dilatometer PCY-1200 Images |